Renovation of a Unity PRC Type 1 Concrete House Repair Watch this slideshow of a LandmarkPRC concrete house PRC repair. The entire process of a Unity Type 1 concrete house from start to finish. Additional information regarding Unity Type 1 Manufacturer
| Unity Structures Ltd / Unity House Construction
| Designer
| Frederick Gibberd
| Period Built
| 1950's
| Number Built
| 19000 Type 1 and 2
| Alternative Name
| Butterley / Unity / Unity Brickclad
|
Physical Attributes and Materials Used - Unity Type 1 houses come in 2 storey semi-detached and terraced construction. Roof is of a medium pitched hipped or gable roof covered in concrete roof tiles. The internal part of the roof is constructed of Timber trusses and with bituminous felt.
- Foundation is approximately 4 foot thick on a floating concrete raft
- Ground floor consists of timber boarding on concrete.
- First floor is built with timber tongue and grove boarding on RSJ floor support beams fixed by twin steel plates and tied in with cross steel supports
- Ceilings are made of plasterboard and supported with 3x2 intersecting wood with RSJ's.
- The exterior part of a Unity house consists of PRC columns/lintels with stack bonded PC panels and Splayed PC blocks to corners . Internal walls are made of standard wall blocks.
Areas which are defective - Cracking of PRC columns
- Cracking and spalling of PRC lintels
- In come cases corrosion of steelwork at interface between PRC Columns and RSJ first floor beams
- And in all cases a high level of chloride content in the PRC panels leading to concrete cancer.
- Some Unity houses may still have asbestos cement roofing sheets. Some councils had these removed in the early 80's due to a connection with cancer.
Environmental and Eco Ratings
- Original Insulation = E rated
- PRC repaired High Density insulation = A Rated
Energy Effeciency - Original Heating = E rated
- New Combi 97% effecient boilder heating (if installed) A rated
Unity houses have always had the advantage of a solid foundation. It is known to have more than twice the foundational materials compared to standard prefab and traditional brick houses. The reason for such a foundation is how the semi detached unity properties are connected together with a balanced beem between both houses just below the roof RSJ's. If you own a unity type 1 or 2 and it is PRC repaired you will find the structure quality and Eco rating is of the highest standard. A recent LandmarkPRC repair produced a X prefabricated unity house with 18 to 19 inch thick walls insulated to the highest standard. Like with all prefabs without this repair to actually sell or even mortgage these properties can be very difficult. A 60 Year Structural guarantee will greatly improve the amount of available lenders and allow you to obtain a low rate low risk mortage.
|
|